INSTITUTE FOR TESTING AND CERTIFICATION

Bitumen testing | Zlín

Testing of asphalts is carried out in Accredited Testing Laboratory No. 1007.1. This part of the laboratory acts as a reference workplace and has approximately 50 accredited test procedures. Thanks to the continuous modernisation of the equipment and the technical level of the staff, the laboratory participates in solving many tasks of the Ministry of Transport of the Czech Republic and is considered a recognised workplace in the transport construction sector.


Links / Downloads

SCOPE OF APPLICATION

  • asphalt binders
  • road petroleum asphalts
  • modified asphalt
  • diluted asphalt
  • asphalt emulsions
  • asphalt grouts for pouring cement concrete joints
  • asphalt binders for the construction of elastic bridge closures
  • single and multi-component cold-applied grouts

SERVICE PROVIDED

  • Petroleum road asphalts
    • Penetration with a needle
    • Softening point by the ring-ball method
    • Resistance to ageing
    • Flash point
    • Fracture point according to Fraasse
    • Solubility in toluene or xylene
    • Paraffin content  
  • Modified asphalts
    • Penetration with a needle
    • Softening point by the ring-ball method
    • Ductility
    • Reversible ductility
    • Force ductility
    • Pendulum cohesion test
    • Fracture point according to Fraasse  
    • Density
    • Cleveland flash point
    • Storage stability at 180°C
    • Resistance to ageing
  • Diluted asphalts
    • Determination of the distillation characteristics of petroleum diluted asphalts
    • Determination of the discharge time of petroleum diluted asphalts/li>
    • Pensky-Martens flash point
  • Asphalt emulsions
    • ZApparent properties
    • Particle polarity
    • Friability with mineral filer ŽKS.CZ
    • Miscibility with cement
    • Miscibility with filer
    • Residue on sieve 0,5 mm
    • Residue on sieve 0,5 mm (7 days storage)
    • Penetrating power
    • Binder content  
    • Oil distillate content
    • Discharge time at 40°C, opening 2 mm, 4 mm
    • Recovery of asphalt binder from emulsion by evaporation
    • Stabilisation of recovered binder
    • Softening point RB of recovered or stabilised binder
    • Needle penetration of recovered or stabilised binder
    • Reversible ductility of recovered or stabilised binder from asphalt emulsion modified with elastomer
    • Pendulum cohesion of recovered or stabilised asphalt emulsion binder modified with elastomer or plastomer, as appropriate
    • Determination of the pH value of asphalt emulsions
    • Determination of the adhesion of asphalt emulsions by water immersion test - Aggregate method
  • Bituminous jointing compounds for cement concrete joints
    • Ring-ball softening point
    • Cone penetration
    • Bulk weight
    • Penetration and elastic regeneration-resilience
    • Stability when heated
    • Creep resistance
    • Resistance to immersion in hydrocarbon fuel
    • Compatibility with asphalt cover
    • Adhesion and cohesion by intermittent stretching
    • Adhesion and cohesion after continuous stretching and compression
  • Single and multi-component cold applied toppings
    • Extrudability
    • Degree of maturation
    • Drying time  
    • Self-leveling ability
    • Creep resistance
    • Loss of volume  
    • Change in mass and volume after immersion in test fuel
    • Resistance to hydrolysis
    • Resistance to flame
    • Cohesion
    • Adhesion/cohesion by intermittent stretching
    • Elastic recovery
    • Adhesion and cohesive properties in continuous stretching after immersion in chemical solutions
  • Oxidised asphalts
    • Softening point BR
    • Penetration with a needle at 25°C
    • Solubility in xylene
    • Loss on heating
    • Flash point
    • Separability of oils
    • Density
    • Dynamic viscosity

ITC RELATED SERVICES

CONTACTS

Ing. Jiří Růžička

Head of the testing laboratory for construction products

Ing. Petra Hrdinová

Head of AZL 1007.1

Ing. Radim Mikač

Testing Specialist

 

Postal address - workplace Zlín:
Institut pro testování a certifikaci, a.s.
Building Testing Laboratory
Svit Campus, building 113
třída Tomáše Bati 5264
760 01 Zlín
Czech Republic