ITC
ITC services regarding ROHS 3

Since July 22, 2019 „RoHS 3“ (2015/863/EC) updated of so called “RoHS 2” directive (No. 2011/65/EC) will come in force, laying down extended requirements on electric and electronic devices.

Except for heavy metals (Pb, Cd, Hg, Cr VI+) and polybrominated flame retardants (PBBs and PDEs) four phthalic acid esters (phthalates) were newly added:
Bis (2-ethylhexyl) phthalate, Butyl benzyl phthalate, Di butyl phthalate a Di iso butyl phthalate in the amount, not exceeded 0,1 w/w % in mass of homogenous material.
Problematic can be thus PVC softened material, like cable insulations then paintings, glues and softened plastics.

Laboratories of ITC are ready to determine all these substances. Years of experiences with such a type of analysis gives you quality assurance regarding analysis results. For request, please, contact:

Ing. David Grebeníček dgrebenicek@itczlin.cz
Ing. Iveta Řezníčková ireznickova@itczlin.cz


new ICP spectrometer in ITC labs

Analytical laboratory has recently purchased new ICP spectrometer Agilent 5800. The spectrometer is intended for determination of elements in water solutions, leachates and mineralisates. It is used mainly for evaluation of food-contact materials, products for children, material analysis of plastics, rubbers and metals. Spectrometer can be also used for determination of elements, which are limited in electro-products by RoHS 3 directive. High sensitivity enable evaluation of products according to many national and European legislations.  


DETERMINATION OF INDIVIDUAL ORGANIC COMPOUNDS (VOC) AND IDENTIFICATION OF THE EMITTED COMPOUNDS BY GC-MS/FID

In autumn 2019 our laboratory of analytical chemistry purchased gas chromatograph Shimadzu GCMS QP 2020 NX with mass spectromecter and flame ionization detector, which is used for analysis of emission of organic substances (VOC) mainly for automotive materials.

Determination of VOC by this method meets the requirements:
- VW 50180 (CLP classification of VOC emission in accordance with Regulation (EC) 1272/2008 included)
- PV 3341
- VDA 277
- VCS 1027,2759


Laboratory is on the List of accepted service laboratories by the VW Group for test according to PV 3341!


Contact: Jitka Bakalová | +420577601453 | jbakalova@itczlin.cz


Trade Fair AMPER 2020 - cancellation

Dear business friends, unfortunately, we have to inform you that the Fair Amper 2020 is cancelled due to the spreading disease COVID-19. For the fair administration is protecting the health of all involved an absolute priority. However, they would not be able to ensure this in the event of the fair being held at the original date, in particular by the inability to prevent the entry of persons at risk. We apologize for any inconvenience.


TERMINATION OF THE REDIRECTION OF OLD TELEPHONE NUMBERS

Dear clients,

As of 31 December 2019, will be TERMINATE THE REDIRECTION OF OLD TELEPHONE NUMBERS of ITC employees who moved from the former Zlín-Louky workplace building to the new Zlín, area Svit, Building 113 workplace.

New telephone numbers can be found on the website of specific service, in the CONTACTS section of the ITC website or on phone request.

For troubleshooting and any questions please contact the ITC’s infoline at +420 572779922.


CALIBRATION | METROLOGY



The main purpose of calibration is to create metrological traceability of the measuring instruments data to  higher order reference standards. Calibration of all measuring instruments is conducted according to the Act on Metrology No. 505/90 Coll. as amended. Calibration services are used especially in chemical, food, agricultural and biological laboratories as well as in laboratories in hospitals, in hygiene and veterinary stations, in waterworks laboratories, in drug substances control and environmental control facilities, in power engineering laboratories,  geology and in other related fields.

Authorised metrology centre, official mark K 123 – The Czech office for standards, metrology and testing (Úřad pro technickou normalizaci, metrologii a státní zkušebnictví – ÚNMZ) authorised Institut pro testování a certifikaci, a.s. (Institute for testing and certification) (ITC) for verifying the following specified meters: elements of meters and measuring assemblies of flowing liquid volumes, temperature gauges (resistance temperature sensors as elements of meters and measuring assemblies of flowing liquid volumes in the range from -20 °C to 100 °C.) and heat and cold meters and their elements (resistance temperature gauges, as elements of temperature meters, in the range from 0 °C to 420 °C).

 

Client's Handbook   Searching the database of certificates  

LIST OF AKL WORKPLACES No. 2222

Workplace Uherské Hradiste Workplace Zlin
   
Workplace Prague Workplace Brno

ELECTRIC QUANTITY METERS

Quantity Range
The best measuring capacity [±]
Direct current voltage (10 ÷ 500) mV
500mV ÷ 1100 V
from 2,4 µV
from 4,7 ppm
Direct current (1 mA ÷ 20 mA)
20 mA ÷ 100 A
tong measurement
20A ÷ 1000A
from 3,5 nA
from 0,011 %
from 0,15 %
Alternating current voltage (0,1 ÷ 40 )mV/(10 Hz ÷ 1 MHz)
40 mV÷ 40 V/(10 Hz ÷ 1 MHz)
(40 ÷ 200) V/(10 Hz ÷ 200 kHz)
(200 ÷ 750) V/(45 Hz ÷ 100) kHz
(750 ÷ 1100) V/(45 Hz ÷ 30 kHz)
from 8 µV
from 0,01%
from 0,01%
from 0,02%
from 0,015%
Alternating current (1 ÷ 100) mA/(10 Hz ÷ 5 kHz)
(100 mA ÷ 2 A)/(10 Hz ÷ 5 kHz)
(2 ÷ 11 A)/(10 Hz ÷ 20 kHz)
(11 ÷ 20A)/(40 ÷ 400)Hz
(20 ÷ 50A)/(40 ÷ 400)Hz
(50 ÷ 100A)/(40 ÷400)Hz
tong measurement
20A ÷ 1000A / (40 ÷ 400) Hz
from 0,015µA
from 0,03%
from 0,06%
from 0,65%
from 1%
from 5,1%
from 0,2 ÷0,6 %
High frequency voltage 20dBmV (10 mV) ÷ 39 V (152dBmV)/(0,1 ÷ 2000) MHz from 2,6%
High frequency output
(impedance 50ohm)
0,01 mW (-20dBm)÷ 3 W (35dBm)/(0,1MHz ÷ 40GHz) MHz
3 W (35dBm)÷ 20 W (40dBm)/(1 ÷ 4000) MHz
from 5 %
from 4,2%
High-frequency attenuation 0 dBm ÷ 100 dBm /(10 ÷ 7000) MHz
3 – 30dB (7GHz – 40GHz)
from 5 %
from 4,2%
from 0,04dBm
Frequency modulation 0,1 kHz ÷ 500 kHz /carrier 4,25 MHz ÷ 1000 MHz, modulation 0,03÷ 100kHz from 0,025 kHz
Amplitude modulation 2 % ÷ 100 % /carrier 55 kHz ÷ 1000 MHz, modulation 0,03÷ 100kHz from 3,1 %
D.C. resistance 0,0001 ? ÷ 100 M? 10 µ? ÷ 18 M?
A.C. resistance 0,1  ÷ 100 M? decimal values / 50Hz ÷ 2 MHz from 0,01
Insulation resistance 10 k? ÷ 5 M?
5 M? ÷ 10 G?
0,25%
1,5%
Capacitance 2pF ÷ 100 µF / 50 Hz ÷ 100kHz
(not accredited: as much as 1MHz)
from 0,1%
Capacitance 1pF ÷ 100 µF decimal values / 1kHz from 0,01%
Inductance 1µH ÷ 100 H / 1kHz (not accredited: as high as 100kH) from 0,4%
Inductance 1µH ÷ 10 H decimal values / 1kHz from 0,1%


Measured instruments and equipment

Panel-mounted instruments A – meter, V – meter, W – meter etc.
Laboratory measuring instruments analogue and digital V - meters, A - meters, W – meters
  L, C, R normal lines, decades
  LF and HF voltage generators, LF and HF synthetizers (BM, TR etc.)
  RLCG bridges
  analogue and digital multimeters (METEX, METRAHIT, KEITHLEY, FLUKE, M1T, HP, SCHLUMBERGR, SOLARTRON, VOLTCRAFT, NORMA etc.)
  osciloscopes and polyscopes (BM, PM, TEKTRONIX, KIKUSUI, HP etc.)
  analyzátory spektrální a obvodové, měřiče a zdroje modulací, modulační analyzátory
  voltage calibrators (d-c, a-c), current sources (d-c, a-c)
  HF voltmeters and wattmeters
  attenuators and terminating elements
Special measuring instruments and testers navigation and communications equipment (NAV, ATC, KTS, CMC etc.)
   
Measuring instruments for external inspectors measuring instruments for inspections of electrical objects (ZO 1, REVEX, MEDITEST etc.)
  measuring instruments for inspections of power lines (EASYTEST, PROFITEST, REVITESTER, PU, PK, QU etc.)
  measuring instruments of insulation, contact and earth resistances (PU, METRISO, DIGIOHM etc.)

FREQUENCY AND TIME

Quantity Range The best measuring ability [±]
Frequency, generation: (0,1; 1; 5; 10) MHz
0,1 Hz ÷ 31,1 MHz
(31,2 ÷ 500) MHz
(500 ÷ 40) GHz
2,3 x 10-11
from 2 x 10-5
0,5 Hz
50 Hz
Frequency, measurement: (0,1; 1; 5; 10) MHz
0,1 Hz ÷ 1 kHz
1 kHz÷ 500 MHz
(500 ÷ 1400) MHz
3, 5 x 10-7
3 x 10-7
3 x 10-10
1 x 10-7
Time, time interval: 1 ÷ 50 ns
50 ns ÷ 200ns
200 ns ÷ 1 ms
10 s÷ 50 s
50 s ÷ 120 h
0,75 ns
1,8%
1,2%
0,85 %
0,06 s
Time at the customer's place (0 ÷ 5) h
(5 - 24 h) h
0,7 s
1,9 s
Revolutions: (10 ÷ 10000) RPM
10000÷ 999999 RPM
0,006 RPM
0,06 RPM
RPM at the customer's place: (5 ÷ 999,99) RPM
(1 000 ÷ 9 999) RPM
(10 000 ÷ 99 999) RPM
0,1 RPM
0,9 RPM
7 RPM

  • Measured instruments and equipment
  • counters, frequency meters
  • generators, oscillators, frequency analyzers
  • frequency converters and changers
  • alternating V and I sources and calibrators
  • stop watches, time meters
  • switching clocks, time relays

PRESSURE GAUGES

Quantity Range The best measuring ability [±]
Deformation pressure gauges
underpressure (air)
underpressure, overpressure (air)
overpressure (oil)
(-98 až < -12) kPa
(>= -12 až =< 12) kPa
(> 12 až 160) kPa
(0,1 až 60) MPa
0,1 kPa
0,015 kPa
0,1 kPa
0,05% MH
Pressure converters
overpressure (oil)
overpressure (air)
overpressure (air)
underpressure (air)
absolute pressure
(0,1 až 60) MPa
(0,4 až 2) MPa
(0 až 400) kPa
(0 až 95) kPa
(0 až 120) kPa
11 kPa + 0,046% MH 0,12 kPa + 0,046% MH
0,04 kPa + 0,046% MH
0,04 kPa + 0,046% MH
0,15%
Digital pressure gauges
overpressure (oil)
overpressure (air)
overpressure (air)
underpressure (air)
absolute pressure
(0,1 až 60) MPa
(0,4 až 2) MPa
(0 až 400) kPa
(0 až 95) kPa
(0 až 120) kPa
11 kPa + 0,046% MH 0,12 kPa + 0,046% MH
0,04 kPa + 0,046% MH
0,04 kPa + 0,046% MH
0,15%

  • Measured instruments or equipment
  • deformation pressure gauges
  • pressure transducers
  • digital pressure gauges


Calibration of pressure gauges can be also performed directly on the customers site

TEMPERATURE METERS

Quantity Range The best measuring ability [±]
Glass thermometers
(division >= 0.1 °C)
(> -40 až < 0 ) °C
0 °C
( >0 až =< 100 ) °C
(>100 až =< 250 ) °C
0,70 °C
0,05 °C
0,07 °C
0,15 °C
Resistance temperature sensors 0 °C
(>0 až =< 100 ) °C
(>100 až =< 250 ) °C
(>250 až =< 350 ) °C
(>350 až =< 600 ) °C
0,03 °C
0,05 °C
0,10 °C
0,20 °C
0,25 °C
Thermoelectric temperature sensors (0 až =< 250 ) °C
(>250 až =< 600 ) °C
(>600 až =< 700 ) °C
(>700 až =< 1200 ) °C
0,20 oC
0,30 oC
1,2 oC
1,5 oC
Direct reading thermometers (electronic, mechanical) 0 °C
(> 0 až =< 100 ) °C
(>100 až =< 250 ) °C
(>250 až =< 420 ) °C
(>420 až =< 600 ) °C
(>600 až =< 700 ) °C
(>700 až =< 1200 ) °C
0,03 °C
0,05 °C
0,07 °C
0,1 °C
0,4 °C
1,4 °C
1,6 °C

  • Measured instruments or equipment
  • platinum resistance thermometers (mimo rozsah akreditace)
  • thermoelectric couples
  • glass thermometers
  • analogue and digital thermometers


The laboratory also provides calibration of temperature meters (temperature sensors, temperature controllers, temperature recorders), which are a fixed part of various process equipments (furnaces, drying lines, presses, plastics moulding machines etc.). The calibration is conducted directly in the plants, with the temperature range of (-20 ÷ +1,200) °C.

RELATIVE HUMIDITY

Quantity Range Best measurement capability [±]
Relative air humidity (10 ÷ 70) %
(70 ÷ 95) %
3,8 %
4,0%

  • Measured instruments or devices
  • (hair) absorption-distortion hygrometers
  • electronic hygrometers
  • optical dew-point hygrometers
  • aspiration hygrometers
  • hygrometers for climatic and humidity chambers


The laboratory also provides on-site calibrations of humidity meters.

LENGTH METERS

Meter Range The best measuring ability [±]
Slide gauges (0 ÷ 200) mm 6 µm
Micrometers (0 ÷ 200) mm 1,1 µm
Dial gauges and digital meters (0 ÷ 100) mm from (0,7 + 1 L) µm
Cylindrical and flat gauges (0 ÷ 200) mm (0,35 + 3 L) µm
Thread gauges, rings (0 ÷ 200) mm (0,7 + 7 L) µm
Precise plug gauges, measuring wires (0 ÷ 50) mm (0,35 + 1 L) µm
Depth gauges (0 ÷ 200) mm 8 µm
Micrometer depth gauges (0 ÷ 100) mm 1,1 µm
Steel gauges (0 ÷ 250) mm 0,05 µm
Angle bars (0 ÷ 180) o 10“
Angle gauges (0 ÷ 360) o 1“
Shape gauges (0 ÷ 300) mm (0,5 + 1 L) µm
Gauge blocks do 100 mm (0,2 + 2 L) µm

  • Other calibrated meters (outside the accreditation)
  • tape rules up to 10 m
  • tape measures up to 50 m
  • calliper rules up to 1000 mm
  • altimeters up to 600 mm
  • tilting tables for artificial horizon
  • water levels and inclinometers

SPECTROPHOTOMETERS

Quantity Range The best measuring ability [±]
Absorbance in the area of UV spectrum (0 ÷ 1,45) 0,0055
Absorbance in the area of VIS spectrum (0 ÷ 1)
(1 ÷ 2)
0,0020
0,0030
Radiation wave length in the area of UV-VIS spectrum (200 ÷ 800) nm 0,035 nm
Wave number in the are of IR spectrum (4 000 ÷ 400) cm-1
(10 000 ÷ 4000) cm-1
0,30 cm-1
0,60 cm-1
Colorimetric coordinates L*, a*, b* L* = (25 ÷ 99)
a* = (-20 ÷ 35)
b* = (-20 ÷ 85)
Colorimetric coordinates L*, a*, b* at lighting C and 65

  • Measured instruments or equipment
  • spectrophotometers for ultraviolet and visible area
  • infra-red spectrophotometers

  • Unaccredited calibrations:
  • calibration filters: holmium – oxide, didym, neutral grey,
  • spark spectrophotometers (by agreement)
  • possible calibrations of other types of spectral meters after mutual consultation. Calibration services Calibrations of spectrophotometers are used mainly in chemical, food-processing, agricultural and biological laboratories, in hospitals, in hygiene and veterinary stations, in waterworks laboratories, in drug testing and environmental workstations, laboratories in energetics, geology and other relative branches.

HARDNESS OF PLASTICS AND RUBBER MATERIALS

Quantity Range The best measuring ability [±]
Hardness SHORE A, C, D (0 ÷ 100) Sh 0,41 ShA (corresponds to 31 mN)
0,16 ShC; 0,16 ShD (corresponds to 71 mN)
Hardness IRHD / N (10 ÷ 100)° IRHD 0,2° IRHD
Hardness IRHD / M (10 ÷ 100)° IRHD 0,9° IRHD

  • Measured instruments or equipment
  • Shore A, C, D type hardness testers
  • IRHD/N, IRHD/M type hardness testers

OZONE MEASUREMENT

Quantity Range The best measuring ability [±]
Ozone concentration (0 ÷ 1000) nmol/mol
(1000 ÷ 5000) nmol/mol
0,025 nmol/mol
2,5 % of the measured value

  • Measured instruments or equipment
  • Ozonators and ozone developers

CONTACTS

Person tel.: e-mail:
Ing. Miroslav Netopil, Head of the Calibration Laboratory (Workplace Uh. Hradiste) +420 572 522 108
(216, 927)
mnetopilPostaitczlin.cz
Ing. Karel Cech, assistant  manager of AKL (Workplace Uh. Hradiste) +420 572 522 219 kcechPostaitczlin.cz
Ing. Pavel Travnicek, assistant  manager  (Workplace Uh. Hradiste) +420 541 633 736 ptravnicekPostaitczlin.cz
Ing. Jaroslav Ambros, manager of AKL (Workplace Zlín) +420 577 601 286 jambrosPostaitczlin.cz
RNDr. Frantisek Kesner, Ph.D., assistant  manager of AKL (Workplace Prague) +420 603 554 788 kesnerPostanicoletcz.cz

 

  • Workplace Uherské Hradiste
    Institute for testing and certification, Inc.
    Sokolovska 573
    686 01 Uherské Hradiste, Czech Republic
     
  • Workplace Brno
    Institute for testing and certification, Inc.
    Areál VUCHZ,
    Krizikova 70
    612 00 Brno, Czech Republic
     
  • Workplace Prague
    Krelovicka 970/6
    104 00  Praha 10 - Uhrineves, Czech Republic

  • Workplace Zlin
    Institute for testing and certification, Inc.
    trida Tomase Bati 299, Louky, 763 02 Zlin, Czech Republic


The person responsible for accuracy of data: Ing. Miroslav Netopil

Updated: 12.6.2020
© ITC - Institut pro testování a cetfifikaci, a.s. | Tel.: +420 572 779 922 | E-mail: itc@itczlin.cz
Webdesign studio
We use cookies that make this site work. By using our services you agree to use them. More about cookies I AGREE