Česky | English | Deutsch | Polski | По-русски | 中文 | 한국어 | Hrvatski | Türkie | ไทย |
ITC
Spielwarenmesse 2019 trade fair invitation

Dear business friends, we invite you to visit our exposition at the International Trade Fair for toys Spielwarenmesse 2019, which will be held 30. 1. – 3. 2. 2019 in Nuremberg. Our stand will be located in Hall H11.1. Stand no. F-05.
 

For detailed information please contact Ms. Barbora Hajkova, e-mail: bhajkova@itczlin.cz
 

Profile of ITC here


BAU 2019 trade fair invitation

Dear business friends, we invite you to visit our exposition at the International Trade Fair for Architecture, Materials and Systems BAU 2019 which will be held 14. 1. – 19. 1. 2019 in Munich. Our stand will be located in Hall A2 Stand no. 423.


For detailed information please contact Ms. Barbora Hajkova, e-mail: bhajkova@itczlin.cz


new gas chromatograph in laboratory of analytical chemistry

In August 2018 our laboratory of analytical chemistry purchased a brand new gas chromatograph, mass spectrometer Shimadzu GCMS-QP2020, equipped by a thermal desorption unit TD-30, which is used for analysis of emissions of organic substances.

 

The spectrometer has a superior sensitivity for organic substances in orders of micro-grams per kg of sample. The system is mainly used for analysis of volatile organic substances (VOC) and condensable substances (FOG) according to the requirements of automotive standard VDA 278, but also for emission measurement of polymer samples to investigate additive system, smell, NIAS (not-intentionally added substances in plastics) etc.

 

Contact for such types of analysis: Franky Puype, phone: +420 577 601 703, e-mail: fpuype@itczlin.cz


New general director

Announcement of change in ITC management.

 

Since September 1, 2018, new general director of the Institute for Testing and Certification has been appointed Mgr. Jiri Hes.

 

RNDr. Radomir Cevelik remains in the position of Board of Directors Vice President.


Determination of phthalic acid esters according to requirements of CPSC

In June 2018 analytical laboratory ITC accredited new procedure for determination of phthalic acid esters in consumer products according to requirements of CPSC (Consumer Product Safety Commission) No. CPSC-CH-C1001-09.4. New standard came in force on April 25, 2018 and released old one No. CPSC-CH-C1001-09.3.

More information concerning phthalate testing are available here


Laboratory of defectoscopy

Testing » Accredited Testing Laboratory No. 1004

The laboratory of defectoscopy is a department of the institute for testing and certification that, as accredited testing laboratory No. 1004, offers specialized services in the field of characterizing defects in materials and measurement of the factors influencing the formation of defects. Using the available expertise of modern science and technology, it is possible, to provide expert forecasting and prevention further defect development. The specialized services of the defectoscopy laboratory are based on many years experience in the areas of research and development (R&D) on polymeric materials and analytical science.

 

Client's Handbook (PDF)
  Thermal desorption  

SERVICES OF THE LABORATORY OF DEFECTOSCOPY

  • Identification the nature of defects
    • using special techniques - thermal desorption  GC-MS, direct inlet-MS, pyrolysis GC-MS demonstrating a very high success rate in the analysis of defects
    • basic analyses of elements to trace their concentration, using XRF, ICP-OES spectroscopy, ICP-MS spectroscopy and AAS
    • chromatography and separation sciences, fully equipped with the current GC and HPLC systems using multiple injection and detection systems
    • special testing offered by the Physical Testing Laboratory (vibration tests, flammability, resistance tests, ageing tests, electrostatics)
  • Measurement of influencing parameters
    • identification and assessment of the parameters influencing the origine of defects
    • defining defects occurring in the production process by adapting analytical conditions on requested parameters
    • diagnosis defining the optimisation of process parameters and prevention of defects
    • to serve customers as an analytical laboratory for research and development (R&D)
  • Prediction and prevention of defects
    • using scientific resources of the ITC (equipment, researchers) together with the technical resources of customers according to their individual requirements can lead to defect prevention
    • cooperation with individual customers with the aim of determining the optimal technological procedures for the production process
    • consulting services of the ITC for preventing the formation of defects with the aim of optimising future process costs

EQUIPMENT

  • gas chromatography with FID and MS detection, liquid chromatography with UV-VIS, fluorescence, RI and conductivity detection
  • fully equipped sample preparation for element analysis by microwave assisted acid digestion
  • atomic absorption spectrometry
  • analytical atomic spectrometry by inductively coupled plasmas combining optical detection (ICP-OES) and mass detection (ICP-MS)
  • X-ray fluorescence spectrometry equipped with EDX (microscope)
  • infrared spectroscopy and infrared microscopy
  • UV-VIS spectroscopy
  • gravimetry, volumetric analysis
  • microscopy, image analysis

OTHER RELATED SERVICES

CONTACTS 

Employee Phone fax e-mail
Ing. Věra Vilímková +420 577 601 634 +420 577 601 389 analytPostaitczlin.cz
Franky Puype, BSc. +420 577 601 704 +420 577 601 389 fpuypePostaitczlin.cz


Post address:
Institute for Testing and Certification, Inc.
Laboratory of Analytical Chemistry and Microbiology
trida Tomase Bati 299, Louky, 763 02 Zlin
Czech Republic

The person responsible for accuracy of data: Ing. Věra Vilímková

Updated: 3.1.2018
 
Webdesign studio
We use cookies that make this site work. By using our services you agree to use them. More about cookies I AGREE